SUBSTATION

USA
OPERATIONS
In
November 2009, a brand new power transformer plant started
operations in Rincon, GA. This plant is equipped with the most
modern equipment in the world and manufacturing CORE and SHELL
technology transformers up to 1500 MVA and 525 kV.
Efacec also manufacturers a full line of
mobile substations,
Appoints
D'Ewart Representatives L.L.C. as manufacturers' representatives for
Alaska, Washington, Oregon, Montana, Idaho & Utah
_________________________________________________________________________
Bonneville
Power
testing-
An 1800kV BIL (500kV line V), 2900lb station post
was tested on the shaker table at Portland State
University. A 500kV disconnect switch was attached at the top
making it a 15' assembly. BPA's
requirements are 0.7G on the single dimension shaker table.
The assembly was tested to the BPA required level,
and
passed
fully.
The test team decided to
intensify the shaker table to determine at what
G-level the insulators would fail. The shaker
table operators maxed out the table at
1.3 G's
and they could not fail the
insulator. This is 180% above BPA's
requirements. A video
of the 1.3G test is available upon request.
Southern
CA
Edison
testing-
Static tests were performed
on (2) 230kV and (1) 500kV designs per SCE substation post
requirements. The insulators were 1050kV BIL, 3000lb (for 230kV), 1050kV
BIL, 3500lB (for 230kV), and a 1800kV BIL, 4000lb (for 500kV). SCE requires
a 'force-deflection' test above and beyond
the standard ANSI
test. The ANSI test requires a batch of
insulators to meet (on average) the rated mechanical load with one pull.
Note the 'average'
wording. Individual insulators can actually fail below the rated cantilever
strength and still meet ANSI requirements. Now, with the
'force-deflection' test, SCE requires 6
push-pull cycles on a single insulator; (3) at
66% and (3) at 100% of full rated
mechanical strength. The reason that this test is very difficult to pass is
due to the fact that after The first pull at 100%
rated load often exceeds the
elastic material property boundary of the
porcelain. The next 'push'
at rated load will then fail the porcelain catastrophically.
The PPC insulators passed all the cycles of the
push-pull at full rated load. To put this in perspective, picture taking
this 500kV insulator and mounting it horizontally. This is an 1800kV BIL
post, so it would cantilever outwards 12+ feet from the wall it is mounted
to. Now, hang a 2-ton SUV from the end of that post!
This SUV example would be equivalent
to a single pull in the force deflection test. The SEVES/PPC
HV post insulator passed the 100%
push
and pull with the same insulator
2 more
times.
_______________________________________________

Secondary Oil Containment
SorbWeb Plus SOC Features
Kinectrics' economical SorbWeb Plus secondary
oil containment system is an effective and reliable passive system that
provides continuous protection against oil spills and leaks associated with
transformers, capacitors, storage tank facilities and other oil-filled
equipment. SorbWeb Plus SOC seals only on coming in contact with oil in the
containment area. Until the system seals, it will allow water from rain or
snowmelt to pass through its "smart"
barrier layers without accumulating, while retaining any oil that
might leak from the transformer.
SorbWeb Plus SOC Benefits
- Engineered containment system using electrical utility best
practices to contain rainfall event, deluge and transformer oil volume
- Unique flexible design to fit equipment arrangement
- Minimum site intrusion / disturbance required for installation
- Passive secondary oil containment and leak management system
- No maintenance costs
- 24/7 protection in the event of a spill or leak
- No mechanical or electrical control systems required
A unique design
SorbWeb Plus is a gravity-based subterranean system that surrounds
oil-filled equipment with geosynthetic materials. The system effectively
traps oil from catastrophic spills and leaks.
Some of the SorbWeb Plus system components are:
- A synthetic impermeable liner
- An adsorbent filter layer
- A retention layer of oil-absorbing material that seals on contact
with hydrocarbons
_______________________________________________________

NEW! AcoustaWall Sound Wall

AcoustaWall reduces noise and light pollution
around transformer yards, along highways and
mass transit lines, and near retail, commercial and
industrial facilities.
It hides unsightly equipment,
discourages intruders, and delivers more noise
reduction per square foot per dollar than concrete,
wood or metal. Plus, it looks better, installs faster,
and lasts longer.
AcoustaWall
By Shakespeare Composite Structures
TRANSMISSION &
DISTRIBUTION


Transmission Line Clearance Issues?
LWS Has a Solution - The PhaseRaiser System
Increase structure height an additional 5',
10' or 15'
NO Line Outage Required
Economical Solution
Low Impact Equipment Used
Field Training Included with
Equipment Rental
No Loss of Structure Reliability or
Decrease in Service Life


If you have groundline clearance problems or are needing
to find innovative ways to increase line capacity, the PhaseRaiser
lifting system is the answer. The PhaseRaiser system is proven to be
more cost effective than new line construction, pole change-outs or
bayoneting
To learn how the PhaseRaiser system can work for you, contact our
engineering department with your structure type, pole sizes and the
range of lifts required.
Laminated Wood Systems' engineering department will analyze existing
structures and recommend the appropriate PhaseRaiser system or related
support members. In addition, you may use Power Line Systems' new
PhaseRaiser Wizard to easily insert a PhaseRaiser into a
PLS-POLE model for analysis of structure strength and verification
of the improved clearances. The PhaseRaiser library is available for
download from the PLS Online Library at
www.powline.com/files/pls_pole.html.
Over 4,000 Structures Raised to Date!
Get A Quote
Please use the worksheet below to request a
quote for PhaseRaiser systems from LWS:

NEW
VORTX™ Vibration Damper
FROM
PREFORMED LINE PRODUCTS

NEW
CUSHION-GRIP™ Suspension FROM PLP

The level of protection provided by the CUSHION-GRIP Suspensions is comparable to a bolted clamp over armor rods. This equates to a reduction in bending strain as high as 50% as compared to bare conductor in a bolted clamp. This reduction in bending strain can be directly related to an increase in overall conductor life.
__________________________________________________________________________
At
Glance Inspection

Toughened
glass insulators cannot be punctured or be
internally cracked. Inspection requires a
simple glance at the string, giving
a complete and reliable assessment of the condition of the insulation. This
means that a crew in a helicopter can inspect over 60
miles of line, or more, per hour.
Inspecting porcelain & composite
insulators requires a testing crew to visit each structure
with insulator strings. Inspecting porcelain
insulators is difficult to do
requiring buzzing
of each unit. Inspecting
composite insulators is sometimes impossible.
_____________________________________________________________________________________________________________
NEW
TOOLS &TEST
SETS

Megger introduces the DELTA4000 Series
High-Voltage
Insulation Diagnostics
Featuring rugged yet lightweight
construction and designed to work reliably in high-interference
areas like substation switchyards, Megger's DELTA4000 series 12-KV
insulation diagnostic system offers time-saving, fully automatic
power factor/tan delta and tip-up testing. Also provided are
facilities for manual measurements where the operator has full
control to set the test parameters fro special testing requirements.

Accurate and dependable
intelligent temperature correction, based on the actual condition of
the test object, can be applied to results using a patented
technique that works with data acquired from a separate dielectric
frequency-response test.
Megger's DELTA4000 series test
set offers comprehensive facilities for assessing the condition of
electrical insulation in all types of high-voltage equipment,
including transformers, bushings, circuit breakers, cables,
lightning arrestors and rotating machinery. They also can be
used for measuring the excitation current of transformer windings.
To ensure accurate results are
obtained even when the instrument is powered from a supply with poor
voltage and frequency stability, the test sets generate their own
test voltage, which is independent of the supply quality. A
further benefit of this approach is that it allows the test voltage
to be varied in frequency for 1Hz to 500 Hz.
DELTA4000 series measure
quantities include voltage, current, power loss, tan delta, power
factor and capacitance. Test results are stored in the unit
and can be sent directly to a printer via USB.
Megger's
New SMRT36 Realy Test Set

The Smart Solution For Protective Relay Testing.
Smaller, lighter and with a higher output power than any other comparable
three-phase instrument in the world, Megger's new
SMRT 36 smart protective relay test set is ideally suited not only for
testing today's installations and legacy plant,
but also for meeting the future challenges associated with testing the smart
grid.
Marking the advent of Megger's
fourth generation of automated relay test sets, the SMRT 36 takes full
advantage the company's patented developments to
produce an instrument that offers higher output current, higher output power
and greater precision than its predecessors, while addressing user demands
for reduced size and weight - it weighs in at just
12 kg.
Introducing the First
Six-Winding Resistance Test Set...

With a Common Lead Set to TTR3xx Series! The NEW
MTO3xx Series of transformer ohmmeters offers the capability of measuring
8-terminal/6-windings automatically without changing test leads.
Faster testing with one-time connection principle,
measures all phases and windings without disconnecting or reconnecting
leads.
The 8-channel design eliminates the need for external jumper cables.
"One clamp per designated bushing"
concept
significantly reduces chance of operator error in making lead set
connections.
Automated eight-terminal/six-winding measurement capability saves time.
Interchangeable lead set with the Megger TTR300 series of 3-phase turns
ratio instruments saves time and money.
FRAX
101
Sweep Frequency Response Analyzer

Smallest and most rugged FRA
instrument in the industry
Highest
possible repeatability by using reliable cable
practice and high-performance instrumentation
Fulfills all
international standards for SFRA measurements
Highest dynamic range
and accuracy in the industry
Wireless
communication and battery operated
Advanced analysis and
decision support built into the software
Imports data from
other FRA test sets
Megger
announces the release of the
SVERKER 750/780
Relay Test Sets

Megger's Relay Test Set is
an Engineer's Toolbox
Megger SVERKER 780 Relay Testing
USB interface
Voltage output with variable frequency
Software Sverker 3.0
High Voltage Power-Output
Freeze the data for post Analysis
Connect 3 SVERKER to simulate a three-phase Relay Tester
Read from external current and voltage
0 to 360 degrees phase shift capability
Optional semi-automated software testing
________________________________________________________________________

WHAT'S NEW
GROUND / JUMPER ASSEMBLY TESTER

VOLTAGE DETECTOR

__________________________________________________________________________________________________

What's New

Montana
Tech Pre-Apprenticeship School, Butte, MT
October, 2009

Seattle
City Light Stretches Out
August
11, 2008
with
Buckingham's BuckSqueeze

Seattle
City Light Apprenticeship Trainers
&
Members
of Synchronized Stretching Team

Buckingham's Harness Beams
